CSA C22.2 • UL 508A • Up to 1000 V

Low Voltage Switchgear

Custom low voltage switchgear up to 1,000 V for power distribution, motor control, and service entrance applications in industrial and commercial facilities.

Up to 1000 VService Entrance RatedModular DesignCSA / UL Listed
Up to 1000 V
Voltage
Up to 3200 A
Max Current
UL 508A
Standard
Custom
Built
Same-Day Quotes
Price and lead time today
2-Year Warranty
Backed by our engineering team
North America Made
Built in Toronto, Ontario
Overview

LV Switchgear for Industrial Power Distribution

Low Voltage Switchgear manages and protects electrical circuits operating up to 1,000 V. Our LV switchgear integrates circuit breakers, contactors, busbars, and metering in modular, free-standing or wall-mount enclosures — custom designed from your single-line diagram and site requirements, compliant with CSA C22.2 and UL 508A.

  • Voltage range up to 600 V (North America) / 1000 V (IEC)
  • Main breaker, main-tie-main, and distribution configurations
  • Service entrance rated with CT / PT metering compartments
  • Copper busbar — continuous, welded, or bolted-splice
  • NEMA Type 1, 4, 12, and 4X enclosure ratings
  • Free-standing or wall-mount multi-section lineups
Low Voltage Switchgear
Switchgear
CSA C22.2 • UL 508A • Up to 1000 V
Features & Upgrades

What's Included

Standard Features
  • Molded case circuit breakers (MCCBs) — fixed or plug-in
  • Air circuit breakers (ACBs) for main and tie sections
  • Non-fused disconnect switches with full-load rating
  • Copper busbar — pre-drilled with NEMA 2-hole pads
  • CT / PT compartment for revenue metering
  • Solid neutral lug and ground bus per section
  • Condensation heater and thermostat per section
  • Infrared (IR) windows for thermographic inspection
  • Non-ferrous aluminum cable entry gland plates
Optional Upgrades
  • +Digital power monitoring (ION, Shark, PM8000 meters)
  • +Zone-selective interlocking (ZSI) between main and feeders
  • +Ground fault protection relay (50GS / 50N)
  • +Surge protective device (SPD) module (IEEE C62.41)
  • +Bus differential protection relay (87B)
  • +Rear access cable management for parallel terminations
  • +Non-ferrous stainless steel gland plates
  • +Witnessed factory acceptance testing (FAT)
Technical Specifications

Full Specifications

ParameterValue
Voltage RangeUp to 600 V AC (North America); 1000 V (IEC)
Phase3-phase, 4-wire (3P4W); single-phase available
Current Rating400 A to 3200 A main bus
Short Circuit RatingUp to 100 kA AIC (application-specific)
Breaker TypeMCCB (fixed / plug-in), ACB (draw-out), fused disconnect
Enclosure TypeNEMA 1, NEMA 12, NEMA 4, NEMA 4X (stainless)
Bus MaterialCopper (standard); aluminum on request
MeteringCT / PT cubicle, revenue-grade utility meters
StandardsCSA C22.2, UL 508A, NFPA 70 (NEC), CEC
Lead Time6–12 weeks from approved single-line diagram
Standards & Compliance

Built to Standard

CSA C22.2
CSA C22.2
Canadian electrical equipment standard for LV switchgear assemblies
UL 508A
Industrial control panel standard — applied to switchgear assemblies
ANSI / IEEE C37
ANSI / IEEE C37
Low voltage AC power circuit breaker performance standards
NFPA 70 / NEC
U.S. national electrical code installation requirements
ESA
Ontario Electrical Safety Authority — service entrance and metering layouts
NETA ATS
NETA ATS
Acceptance testing specifications for commissioning
Applications

Where It's Used

  • 480 V and 600 V industrial power distribution centres
  • Service entrance switchgear with utility CT / PT metering
  • Generator paralleling and synchronizing switchgear
  • Motor control centre (MCC) feed and tie switchgear
  • Commercial campus main distribution equipment (MDE)
  • Data centre main and sub-distribution switchgear
  • Water and wastewater treatment plant PDCs
  • Oil & gas facility power distribution centres
End-to-End Services

From design and specification through factory testing, commissioning, and ongoing maintenance — Candron delivers at every phase.

  • Engineering drawings and coordination studies
  • Factory acceptance testing (FAT) with full reports
  • Site commissioning and protection settings
  • Spare parts, training, and maintenance support
FAQ

Common Questions

LV switchgear and switchboards serve similar functions but differ in design and duty. Switchgear typically uses air circuit breakers (ACBs) or molded-case breakers in a fully compartmented, individually isolated design with higher interrupting ratings and draw-out capabilities. Switchboards are a cost-effective alternative where the higher fault-current ratings and draw-out modular features of switchgear are not required.

Yes. We design service entrance rated LV switchgear with CT / PT metering compartments, tamper-resistant sealing provisions, and ESA / AHJ acceptance layouts. These are coordinated with the local utility (Hydro One, Alectra, Enbridge) for meter form and landing pad requirements.

We offer NEMA Type 1 (general purpose), Type 12 (dust-tight), Type 4 (watertight), and Type 4X (watertight, corrosion-resistant stainless steel). For outdoor applications we also supply free-standing kiosk enclosures with climate control and HVAC.

Yes. Multi-section lineups can be designed to split at predetermined bus joint locations for rigging through stairwells, doorways, or restricted areas. Bus joints use copper splice bars with bolted connections, and the split sections are field-connected during installation.

Get a Quote

Ready to Spec
Your Project?

Our engineering team responds with specs, lead times, and pricing the same day. Tell us what you need:

  • System voltage (V) and available fault current (kA)
  • Main bus current rating (A)
  • Number of feeder circuits and breaker schedule
  • Utility metering requirements (CT / PT form and class)
  • Enclosure type (NEMA 1, 12, 4, or 4X)
  • Site access constraints (doorway / stairwell dimensions)
Same-Day Response

Send us your project details and we'll respond with a price, lead time, and any clarifying questions — typically within a few hours.

Request a Quote →Or call us directly