UL 1558 + CSA C22.2 • IEEE C37 • Canada & United States

Switchgear — Protection,
Control, Continuity

Low- and medium-voltage switchgear engineered for safety, arc-flash mitigation, and operational uptime. Up to 29 kV and 6000 A.

Arc-Flash ReadyWithdrawable BreakersSCADA IntegrationESA Compliant
Same-Day Quotes
Price and lead time today
2-Year Warranty
Backed by our engineering team
North America Made
Built in Toronto, Ontario
Overview

Built for Protection,
Designed for Uptime

Switchgear isolates faults, protects equipment, and keeps your process running. Our designs align protection settings with utility requirements and downstream coordination. We support indoor arc-resistant lineups and outdoor weatherproof enclosures.

  • Voltage ranges: LV up to 600 V, MV 5–29 kV
  • Breaker technologies: ACB, VCB, SF6 alternatives
  • Relaying: ANSI/IEC curves, differential and distance options
  • Remote operation & SCADA gateways
Candron switchgear assembly
29 kV
Max Voltage
6000 A
Max Current
UL / CSA
Compliance
Arc-Rated
Safety
Types & Specifications

Switchgear Configurations

Explore our range of switchgear configurations engineered for protection, safety, and continuous uptime.

Low Voltage Switchgear
Standard Features
  • ACBs and MCCBs with selective coordination
  • Integrated revenue metering
  • Main-tie-main configurations
  • Zone-selective interlocking (ZSI)
  • Ground fault protection
  • Copper bus bar — continuous rating
Optional Upgrades
  • +Arc-flash resistant (ARST) enclosure
  • +Remote racking device for VCBs
  • +Infrared inspection windows
  • +Bus differential protection relay
  • +High-resistance grounding (HRG) system
  • +Remote monitoring gateway
Voltage
Up to 600 V
Current
Up to 6000 A
Interrupting Rating
Up to 85 kA
Features
ACBs, MCCBs, metering
Standards
UL 1558, CSA C22.2
Metal-Clad Medium Voltage
Standard Features
  • Withdrawable VCBs with three-position isolation
  • Full bus compartmentalization
  • Protection relays: 50/51, 27/59, 67, 87
  • Voltage range: 5–29 kV
  • Interlocked safety shutters
  • Front and rear cable entry options
Optional Upgrades
  • +Arc-resistant type (ARST) construction
  • +Motor-operated racking mechanism
  • +PT cubicle with revenue metering
  • +Partial discharge monitoring
  • +Battery-backed control power
  • +SCADA / IEC 61850 gateway
Voltage
5–29 kV
Current
600–4000 A
Interrupting Rating
Up to 40 kA
Features
Withdrawable VCBs, arc-rated
Standards
IEC 62271-200, IEEE C37
Metal-Enclosed Load-Interrupter
Standard Features
  • Load-break switches and current-limiting fuses
  • Outdoor weatherproof enclosure (IP54+)
  • Pad or skid-mounted installation
  • Full-voltage transformer protection
  • Accessible cable termination compartments
  • CSA and IEEE C37.20.3 compliant
Optional Upgrades
  • +Motor-operated switch actuator
  • +Fault indicator LEDs
  • +Remote monitoring SCADA gateway
  • +Additional cable termination compartment
  • +Fuse-saving scheme with recloser coordination
  • +Stainless steel enclosure option
Voltage
5–27.6 kV
Current
600–2000 A
Interrupting Rating
Up to 20 kA
Features
Fused, outdoor weatherproof
Standards
CSA C22.2, IEEE C37.20.3
Service-Entrance Rated
Standard Features
  • Main breaker / tie breaker with ground fault
  • Revenue metering cubicles (CT/PT)
  • ESA and AHJ acceptance layouts
  • Custom relay coordination
  • Utility interface protection (27/59, 81)
  • As-built drawings and test reports
Optional Upgrades
  • +Arc-flash study and PPE labelling
  • +Witnessed factory acceptance testing (FAT)
  • +Remote annunciation panel
  • +On-site commissioning and protection setting
  • +Power quality analyser integration
  • +Utility coordination study and report
Voltage
Up to 29 kV
Current
Site-specific
Interrupting Rating
Site-specific
Features
Utility-approved, revenue metering
Standards
CSA, ESA, UL
Standards & Compliance

Built to Standard

UL 1558
U.S. low voltage switchgear standard
CSA C22.2
CSA C22.2
Canadian electrical product standards
IEC 62271-200
IEC 62271-200
Medium voltage AC switchgear
IEEE C37 Series
IEEE C37 Series
Switchgear standards and testing
ANSI / NETA
ANSI / NETA
Factory acceptance testing protocols
ESA / AHJ
Ontario authority acceptance layouts
Applications

Where Our Switchgear is Deployed

  • Utilities & substations
  • Mining & heavy industry
  • Oil & gas facilities
  • Industrial plants & manufacturing
  • Data centers
  • Commercial campuses
  • Transit & traction power
  • Healthcare facilities
End-to-End Services

One team. Design to commissioning.

Protection settings, coordination studies, factory testing, site commissioning, and ongoing maintenance — all from the same team that built your equipment.

View Commissioning Services →
FAQ

Frequently Asked Questions

Switchgear supports higher fault current ratings and includes protective relay functions for isolation and fault clearing. Switchboards focus on LV distribution with circuit breakers and metering, without the same fault interruption ratings.

Yes — we deliver arc-flash hazard analysis studies, PPE labels, and mitigation strategies such as zone-selective interlocking (ZSI) and high-resistance grounding.

Yes. Witnessed FAT is available for your project team or third-party inspector. We perform insulation resistance, primary injection, contact resistance, and full functional tests — with a comprehensive report written for both technical and non-technical stakeholders.

Get a Quote

Request Switchgear Pricing

What to Include in Your Inquiry
  • Site voltage and main current rating
  • One-line diagram or utility requirements
  • Indoor / outdoor, arc-rated needs
  • SCADA or relay protection preferences
  • Required delivery timeline
  • Witnessed FAT requirements
Response within 1 business day

Same-day lead time quote.
Speak directly with our engineers.

Our engineering team reviews every inquiry personally — no automated responses, no gatekeeping.

Request a Quote →Or call +1 (647) 616-2595

See What We Can Build For You

Built in Canada — reach our engineering team directly for specs, quotes, and lead times.