IEC 62271-200 • IEEE C37.20.2 • 5–29 kV

Metal-Clad Medium Voltage Switchgear

Fully compartmented, draw-out vacuum circuit breaker (VCB) lineups for medium-voltage power distribution. Arc-resistant type (ARST) options and SCADA integration available from 5 kV to 29 kV.

Draw-Out VCBsArc-Resistant OptionIEC 62271-200IEEE C37.20.2
5–29 kV
Voltage Class
600–4000 A
Main Rating
40 kA
Interrupting Rating
Arc-Rated
Safety Option
Same-Day Quotes
Price and lead time today
2-Year Warranty
Backed by our engineering team
North America Made
Built in Toronto, Ontario
Overview

Draw-Out VCBs with Full Bus Compartmentalization

Metal-clad switchgear is the most robust MV switchgear classification — every functional element (bus, breaker, cables, instruments) is in a separate grounded compartment. Our lineups meet IEC 62271-200 and IEEE C37.20.2 with full three-position (connected/test/disconnected) isolation.

  • Voltage range: 5 kV, 15 kV, 27.6 kV, and 29 kV classes
  • Vacuum circuit breakers (VCBs) with draw-out chassis
  • Grounded barriers between all functional compartments
  • Arc-resistant type A, B, or C construction (optional)
  • Digital protection relays: 50/51, 27/59, 67, 87T, 87B
  • Front and rear cable entry; top or bottom bus options
Metal-Clad Medium Voltage Switchgear
Switchgear
IEC 62271-200 • IEEE C37.20.2 • 5–29 kV
Features & Upgrades

What's Included

Standard Features
  • Withdrawable VCBs with three-position isolation
  • Full compartmentalization (bus, breaker, cable, instrument)
  • Interlocked safety shutters — breaker cannot close out of position
  • Protection relays: 50/51, 27/59, 67N, 87 bus differential
  • Front-accessible control panel with local/remote selector
  • Voltage indicator lights per NFPA 70E safe work practice
  • Grounded metal barriers between all compartments
  • Standard steel or stainless steel enclosure options
Optional Upgrades
  • +Arc-resistant (ARST) type construction with pressure relief ducts
  • +Motor-operated racking mechanism for remote breaker positioning
  • +PT cubicle with revenue-grade metering (class 0.2S)
  • +Partial discharge monitoring system (on-line PD)
  • +Battery-backed DC control power supply
  • +SCADA / IEC 61850 communication gateway
  • +Witnessed factory acceptance testing (FAT)
  • +Arc-flash study and labelling
Technical Specifications

Full Specifications

ParameterValue
Voltage Class5 kV, 15 kV, 27.6 kV, 29 kV
Main Bus Rating600 A, 1200 A, 2000 A, 3000 A, 4000 A
Interrupting RatingUp to 40 kA symmetrical (class dependent)
Breaker TechnologyVacuum Circuit Breaker (VCB) — draw-out
CompartmentalizationMetal-clad: bus, breaker, cable, instrument — grounded barriers
Bus MaterialCopper, silver-plated contact surfaces
Protection RelaysANSI 50/51, 27/59, 67/67N, 87T, 87B, 81
CommunicationModbus RTU/TCP, IEC 61850, DNP3 (optional)
Arc-Resistant OptionARST type A, B, or C per IEEE C37.20.7
EnclosureNEMA 1 indoor; outdoor weatherproof housing available
StandardsIEC 62271-200, IEEE C37.20.2, CSA C22.2
Lead Time8–16 weeks typical; expedited available
Standards & Compliance

Built to Standard

IEC 62271-200
IEC 62271-200
Metal-enclosed MV switchgear — alternating current up to 52 kV
IEEE C37.20.2
IEEE C37.20.2
Metal-clad switchgear standard — draw-out, fully compartmented
IEEE C37.20.7
IEEE C37.20.7
Guide for testing metal-enclosed switchgear rated up to 38 kV for internal arcing faults
CSA C22.2
CSA C22.2
Canadian electrical safety standard for MV switchgear assemblies
ANSI C37 Series
ANSI C37 Series
Circuit breaker and switchgear application and testing standards
NETA ATS
NETA ATS
Acceptance testing specifications applied at FAT and site commissioning
Applications

Where It's Used

  • Utility distribution and substation feeder switching
  • Mining primary distribution centres (PDC)
  • Industrial plant main medium-voltage distribution
  • Oil & gas upstream and midstream power systems
  • Data centre utility service entrance at 13.8 kV
  • Renewable energy generation interconnects
  • Transit traction power substations
  • University and hospital main campus substations
End-to-End Services

From design and specification through factory testing, commissioning, and ongoing maintenance — Candron delivers at every phase.

  • Engineering drawings and coordination studies
  • Factory acceptance testing (FAT) with full reports
  • Site commissioning and protection settings
  • Spare parts, training, and maintenance support
FAQ

Common Questions

Metal-clad (IEEE C37.20.2) has individual grounded metal barriers between all functional compartments — bus, breaker, cables, and instruments — with draw-out breakers and interlocked shutters. Metal-enclosed is a broader term covering assemblies where not all compartments are individually separated; load-interrupter switchgear is a common example.

Yes. We offer ARST type A, B, and C construction per IEEE C37.20.7, including pressure relief ducts routed to safe discharge zones. Arc-resistant designs are validated through internal arcing fault testing.

We work with most major relay manufacturers (Schweitzer, GE/Multilin, ABB, Beckwith, Basler). Standard packages include overcurrent (50/51), voltage (27/59), directional (67), and differential (87). IEC 61850 and DNP3 gateways are available.

Get a Quote

Ready to Spec
Your Project?

Our engineering team responds with specs, lead times, and pricing the same day. Tell us what you need:

  • Nominal voltage and number of feeders
  • Main bus and feeder current ratings
  • Available fault current (kA) at the bus
  • Protection relay functions and SCADA protocol
  • Arc-resistant classification required (if any)
  • Indoor or outdoor; single-ended or double-ended
Same-Day Response

Send us your project details and we'll respond with a price, lead time, and any clarifying questions — typically within a few hours.

Request a Quote →Or call us directly