UL 1558 • CSA C22.2 • Up to 600 V / 6000 A

Low Voltage Switchgear

Main, distribution, and end-of-line switchgear up to 600 V and 6000 A — selective coordination, arc-flash protection, and SCADA-ready layouts built to North American standards.

ACBs / MCCBsUL 1558 ListedArc-Flash ReadyESA Compliant
Up to 600 V
Voltage Class
Up to 6000 A
Main Rating
85 kA
Interrupting Rating
UL 1558
Standard
Same-Day Quotes
Price and lead time today
2-Year Warranty
Backed by our engineering team
North America Made
Built in Toronto, Ontario
Overview

Selective Coordination from the Main to the Branch

Our low voltage switchgear lineups are engineered for institutional, industrial, and infrastructure applications where fault clearing speed, coordination integrity, and maintenance safety are non-negotiable. Every lineup is built in-house and tested before shipment.

  • Air circuit breakers (ACBs) and moulded case circuit breakers (MCCBs)
  • Main-tie-main (MTM) and double-ended substation configurations
  • Zone-selective interlocking (ZSI) for fast, selective fault clearing
  • Integrated revenue metering and power quality monitoring
  • Indoor NEMA 1 or outdoor NEMA 3R / 4X enclosures
  • Copper bus rated for continuous current with thermal bracing
Low Voltage Switchgear
Switchgear
UL 1558 • CSA C22.2 • Up to 600 V / 6000 A
Features & Upgrades

What's Included

Standard Features
  • ACBs and MCCBs with selective coordination
  • Integrated revenue metering cubicle
  • Main-tie-main configuration options
  • Zone-selective interlocking (ZSI)
  • Ground fault protection relay
  • Copper bus bar — continuous rating with full bracing
  • Front-accessible cable compartments (top or bottom entry)
  • Metered and un-metered feeder sections
  • Mimic bus with LED status indication
  • Full-voltage control power transformer (CPT)
Optional Upgrades
  • +Arc-flash resistant (ARST) enclosure with pressure relief
  • +Remote racking system for breaker withdrawal
  • +Infrared inspection windows at bus joints
  • +Bus differential protection relay (87B)
  • +High-resistance grounding (HRG) system
  • +Remote monitoring gateway (Modbus / IEC 61850)
  • +Witnessed factory acceptance testing (FAT)
  • +Power quality analyser integration
  • +Emergency power-off (EPO) module
Technical Specifications

Full Specifications

ParameterValue
Voltage ClassUp to 600 V (208/347/480/600 V)
Main Current RatingUp to 6000 A (continuous)
Interrupting RatingUp to 85 kA symmetrical
Bus MaterialCopper, silver-plated contact surfaces
EnclosureNEMA 1, 3R, or 4X
Breaker TechnologyACB (Air Circuit Breaker), MCCB
Protection RelaysLSIG, ZSI, ground fault (50/51G)
MeteringRevenue-grade metering, power quality analyser
Control Power120 V AC via CPT; battery backup option
FinishANSI 61 grey powder coat; custom colour available
StandardsUL 1558, CSA C22.2 No. 31, NEMA PB 2
Lead Time4–10 weeks typical; expedited available
Standards & Compliance

Built to Standard

UL 1558
U.S. low voltage switchgear standard — deadfront construction, short-circuit ratings
CSA C22.2 No. 31
CSA C22.2 No. 31
Canadian switchgear standard for LV deadfront assemblies
IEEE C37 Series
IEEE C37 Series
Circuit breaker testing and application standards
ANSI C37.20.1
ANSI C37.20.1
Metal-enclosed low voltage power circuit breaker switchgear
ESA / AHJ
Ontario Electrical Safety Authority inspection-ready layouts
NETA ATS
NETA ATS
Acceptance testing specifications for factory and field testing
Applications

Where It's Used

  • Main switchgear in hospitals and healthcare facilities
  • Data centre primary and secondary distribution
  • University campuses and institutional buildings
  • Industrial plant main and sub-distribution
  • Commercial high-rise and mixed-use towers
  • Transit and transportation facilities
  • Mining surface substations
  • Service entrance (utility point of delivery)
End-to-End Services

From design and specification through factory testing, commissioning, and ongoing maintenance — Candron delivers at every phase.

  • Engineering drawings and coordination studies
  • Factory acceptance testing (FAT) with full reports
  • Site commissioning and protection settings
  • Spare parts, training, and maintenance support
FAQ

Common Questions

Low voltage switchgear (UL 1558) is designed for higher short-circuit current ratings and includes protective relay functions for selective fault isolation. Switchboards (UL 891) focus on LV branch distribution and metering — they are typically not rated for the same interrupting levels as switchgear.

Yes — we deliver arc-flash hazard analysis studies, PPE level labels, and mitigation strategies such as zone-selective interlocking (ZSI) and high-resistance grounding (HRG), coordinated with your utility protection settings.

Yes. Witnessed FAT is available for your project team or a third-party inspector. Tests include insulation resistance, primary injection, contact resistance, relay functional, and full operational checks — with a comprehensive documentation package.

Standard lead times are 4–10 weeks from drawing approval, depending on scope and current shop loading. Expedited schedules are available — contact us to discuss your project timeline.

Get a Quote

Ready to Spec
Your Project?

Our engineering team responds with specs, lead times, and pricing the same day. Tell us what you need:

  • Service voltage and main current rating
  • Single-line diagram and utility interconnection requirements
  • Indoor/outdoor and enclosure type (NEMA 1 / 3R / 4X)
  • Metering requirements (revenue or sub-metering)
  • Relay / protection package and SCADA gateway needs
  • Arc-flash study requirements